LabWindows/CVI for Windows 95 and NT, Version 4.0.1
Documentation File
(c) Copyright 1993-1996 National Instruments Corporation.
All rights reserved.
Product and company names listed are trademarks
or trade names of their respective companies.
This file contains installation and programming considerations and
changes that are too recent to be included in the printed LabWindows/CVI
documentation.
Before Installation
-------------------
1. If you have been using version 3.1 or earlier of LabWindows/CVI, it is
recommended that you do not overwrite it. Instead, you can install
the 4.0.1 version in a new directory.
2. If you have been using LabWindows/CVI 3.1 or earlier, you should make
backup copies of your .UIR files. Once .UIR files have been saved in
version 4.0.1, they are partially compatible with version 3.1 and 3.0.1.
You can load them into 3.1 and 3.0.1, but if you save them you lose the
new 4.0.1 features. Once .UIR files have been saved in version 4.0.1, they
are no longer compatible with version 3.0.
3. If you are installing on Windows NT, you must have Windows NT version
3.51 or greater.
4. You must choose the Custom Installation option to install the complete
Windows SDK from the CD-ROM version of the LabWindows/CVI FDS.
Some Windows SDK header and import library files are installed with the
disk version. The Windows SDK help file is only available with the
CD-ROM version of LabWindows/CVI FDS.
5. The LabWindows/CVI Run-time Engine is now installed as part of the
LabWindows/CVI installation. An extra Run-time Engine installation disk
(or subdirectory on the CD-ROM installation) is included with the product.
6. If you plan to use GPIB, VXI, DAQ or VISA with LabWindows/CVI, you
must have a compatible driver from National Instruments. There are
some limitations detailed within this document, the manuals, and the
"readme" files for each I/O driver. Please review this documentation
before installing and programming with each I/O library.
The following National Instruments hardware software drivers are included
on the CD-ROM version of the LabWindows/CVI. The \Drivers\ subdirectory
contains the following.
\Daq\ - Version 4.9.0 (Please read section on
NI-DAQ below)
\Visa\ - Version 1.03 release
\Gpib\
\Win95\
\Compat\ - Version 1.0 (for Windows 3.1 drivers
used in Windows 95, a thunking DLL)
\V11\ - Version 1.1 (Native 32-bit DLL)
\WinNT\
\V10\ - Version 1.0 (*)
(Only supports AT-GPIB/TNT & AT-GPIB)
\V102a2\ - Version 1.02 alpha release 2 (*)
(support for GPIB callbacks was added)
(*) Note: When you install the NI-GPIB driver for Windows NT directly
from the CD-ROM, the SETUP.EXE can fail and report an
application error. Copy the NI-GPIB installation image to
your harddrive and try the installation again.
7. If you plan to use GPIB with LabWindows/CVI, you must have a 488.2-
compatible GPIB board from National Instruments. You also must have
installed the NI-488.2 software for Windows 95 or Windows NT. For
Windows NT, the version 1.0 driver only supports the AT-GPIB\TNT and
AT-GPIB boards.
If you plan to use GPIB callbacks under Windows 95 or Windows NT, you
must install the alpha or beta NI-GPIB drivers located on the
LabWindows/CVI CD-ROM or get the released versions of this driver
when available from National Instruments.
8. If you plan to use the Data Acquisition Library with LabWindows/CVI,
you must have a Data Acquisition board from National Instruments. You
also must install the NI-DAQ software from the distribution diskettes
for NI-DAQ version 4.8.5 or later. NI-DAQ 4.9.0 is included on the
CD-ROM version of LabWindows/CVI.
When installing NI-DAQ 4.9.0 or later, do so AFTER installing
LabWindows/CVI so that the appropiate support files will be
copied into the LabWindows/CVI directories. Select the "LabWindows/CVI"
option in the NI-DAQ installation.
The 4.8.5 version of NI-DAQ was created prior to the existence of
LabWindows/CVI 4.0.1. Under Windows 95, the "LabWindows/CVI" option
in the NI-DAQ 4.8.5 installation copies files into the LabWindows/CVI
directory tree that do not work with LabWindows/CVI 4.0.1.
To use NI-DAQ 4.8.5 with LabWindows/CVI 4.0.1, do the following.
- Install NI-DAQ 4.8.5. Under Windows 95, choose the "Third Party
Compilers and DAQWare" option instead of the "LabWindows/CVI" option.
Under Windows NT, choose the "Install NI-DAQ for Windows NT" option.
- Install the LabWindows/CVI Support Files for NI-DAQ 4.8.5 diskette
that comes with LabWindows/CVI. If you have the CD-ROM version of
LabWindows/CVI, the disk image is located on the CD in the \NIDAQ485\
subdirectory.
9. If you plan to use the NI-VXI Library with LabWindows/CVI, you must
have installed the NI-VXI Software Interface drivers. For Windows
95, you must use the NI-VXI Windows 3.1 drivers with the NI-VXI
Upgrade for Windows 95, or use a native Windows 95 NI-VXI driver.
The NI-VXI Upgrade for Windows 95 contains a thunking DLL to
interface the 32-bit LabWindows/CVI environment to the Windows 3.1
16-bit drivers.
For Windows NT, National Instruments has NI-VXI drivers for AT-MXI,
PCI-MXI-2, VXIpc-486 Model 500 Series and VXIpc-850 Series. Please
contact National Instruments for more information.
10. If you want to convert LabWindows/DOS programs to run under
LabWindows/CVI, read Chapter 12 of the Getting Started with
LabWindows/CVI manual, entitled "Converting LabWindows for DOS
Applications".
Additions and Corrections to Printed Documentation
--------------------------------------------------
Using NI-DAQ on Windows NT
Some of the exported function prototypes for the NI-DAQ 4.8.5 DLL
for Windows NT are different than the function prototypes for
Windows 3.1 and Windows 95. Please review the Release Notes for more
information.
The NI-DAQ version 4.8.5 interface for Windows NT is different than
the NI-DAQ interface for Windows 95. To present a unified interface
across Windows 95 and NT, LabWindows/CVI for Windows NT uses the
Windows 95 NI-DAQ interface.
The functions listed in section "Differences in Current NI-DAQ API
for Windows NT" in the LabWindows/CVI for Windows Release Notes are NOT
supported in version 4.8.5 and 4.9.0 of NI-DAQ for Windows NT. As
mentioned, National Instruments will release a new version of NI-DAQ
for Windows NT in the future that is equivalent to the Windows 95
interface.
Use of AT-MIO E Series data acquisition DAQ products is not supported
under Windows NT. As you may know, Windows NT does not have ISA Plug
and Play (PnP) capability. This means that Windows NT can neither
recognize nor communicate with ISA PnP boards. If you have an
AT-MIO E Series board and are considering Windows NT you have two options.
- use Windows 95 until Windows NT has ISA PnP capability,
or
- call your National Instruments Inside Sales Representative to
discuss exchange options for your AT-MIO E Series board with a
legacy AT-MIO board.
NI-DAQ error codes on Windows 95 and NT
Two new NI-DAQ functions have been added to handle error codes.
1) GetNIDAQErrorString
This function converts error codes returned by a Data Acquisition
Library function into a meaningful error message.
The function prototype is as follows,
char *GetNIDAQErrorString (short Error_Code);
2) ConvertToNewNIDAQErrorCode
The error codes returned by NI-DAQ version 4.9.0 and later are
different than those returned by NI-DAQ version 4.8.5 and earlier.
The ConvertToNewNIDAQErrorCode function converts old error codes
into a new error codes. If you pass a new error code (or an
unknown error code) to this function, the function returns the
value passed in.
This function is useful if your program checks for specific error
codes and may be used on computers with different versions of NI-
DAQ.
Note: Although version 4.9.0 of the NI-DAQ DLL for Windows NT
returns the old-style error codes, the Data Acquisition
Library automatically converts these to the new error
codes. This presents a unified interface across Windows
95 and NT.
The function prototype is as follows,
short ConvertToNewNIDAQErrorCode (short Error_Code);
Using GPIB Callbacks on Windows 95 or Windows NT
If you plan to use GPIB callbacks under Windows 95 or Windows NT, you
must install an NI-GPIB driver that supports this feature. Refer to
GPIB Library Chapter in the Standard Library Reference Manual for more
information.
Windows NT NI-GPIB alpha version 1.02 and ibInstallCallback
Under Windows NT, the NI-GPIB alpha driver does not properly place an
opened board online and CIC until the first device-level call that
requires the device to be online and CIC. If the board is in this
state and a call is issued to ibInstallCallback, subsequent callbacks
do not occur. To work around this problem, either make the board-level
call to ibsic, or make a device-level calls (e.g., ibwait 0), and it
has a side-effect of placing the connect board online and making
it CIC. Note, calls that just configure the device like ibpad do NOT
have this side-effect.
Specifying an Application Icon and Title when creating an executable
with a external compiler
Application Icon - The first icon compiled into the executable is the
icon used. Add a resource to your executable and put your icon in
the resource.
Application Title - The application title is a string in the string
table for your executable. Add a resource to your executable, then
create a string table. Insert a new string with an ID of 65535, and
this string is used as the application title.
Instrument Driver Library
The National Instruments Instrument Driver Library is included on
the CD-ROM version of the LabWindows/CVI. The \Instr\ subdirectory
contains the following subdirectories.
\camac\ - CAMAC Instrument Drivers
\gpib\ - GPIB Instrument Drivers
\serial\ - Serial Instrument Drivers
\vxi\ - VXI Instrument Drivers
Using NetDDE on Windows 95 and NT
---------------------------------
To use NetNDDE under Windows 95 and NT, you must create a DDE Share.
A DDE Share exports a DDE server for use by a remote client
through NetDDE.
The method for creating a DDE Share under Windows 95 is
different than the method under Windows NT. In both methods,
the following terms are used.
- "sharename" is a name that you create and pass as the third parameter
to the ConnectToDDEServer function in the DDE Library.
- "topic" is the server topic that is being shared.
- "server" is the server name. In a LabWindows/CVI application that
is acting as a DDE server, it is the string passed as the first
parameter to the RegisterDDEServer function. In other applications,
it generally is the name of the server program, for example, "excel".
Adding a DDE Share Under Windows 95
To add a DDE Share, run the following command.
cvi\bin\nddeshar ADD sharename topic server
To remove a DDE Share run the following command.
cvi\bin\nddeshar DELETE sharename
Note: When using NetDDE on Windows 95, you must first run
\windows\netdde.exe on both the client and server machines.
You can add a shortcut to it in your Startup folder so that
it runs every time you start Windows 95.
Adding a DDE Share Under Windows NT
Run winnt\system32\ddeshare.exe.
Choose DDE Shares from the Shares menu.
In the dialog that appears, click on the 'Add A Share' button to bring up
the DDE Share Properties Dialog.
Type in the sharename in the Share Name edit box.
Leave the 'Old Style' and 'New Style' rows empty.
In the 'Static' row, enter the server and topic in the 'Application Name'
and 'Topic Name' columns respectively.
Click on the 'Permissions' button to setup the DDE Share Name permissions.
In the Permissions dialog, click on Everyone and then change to type of
access to Full Control.
Click on the OK button to exit the Permissions Dialog.
Click on the OK button to exit the DDE Share Properties Dialog.
In the DDE Shares dialog, click on the line containing the sharename you
just entered.
Click on the 'Trust Share' button to bring up the Trusted Share Properties
dialog.
Check the 'Initiate To Application Enable' checkbox.
Click on the OK button to exit the Trusted Share Properties dialog.
Click on the OK button to exit the DDE Shared dialog.