Files
Aaru/Aaru.Tests.Devices/SCSI/Plasmon.cs

458 lines
16 KiB
C#

// /***************************************************************************
// Aaru Data Preservation Suite
// ----------------------------------------------------------------------------
//
// Filename : Plasmon.cs
// Author(s) : Natalia Portillo <claunia@claunia.com>
//
// Component : Aaru device testing.
//
// --[ License ] --------------------------------------------------------------
//
// This program is free software: you can redistribute it and/or modify
// it under the terms of the GNU General Public License as
// published by the Free Software Foundation, either version 3 of the
// License, or (at your option) any later version.
//
// This program is distributed in the hope that it will be useful,
// but WITHOUT ANY WARRANTY; without even the implied warranty of
// MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
// GNU General Public License for more details.
//
// You should have received a copy of the GNU General Public License
// along with this program. If not, see <http://www.gnu.org/licenses/>.
//
// ----------------------------------------------------------------------------
// Copyright © 2011-2022 Natalia Portillo
// ****************************************************************************/
namespace Aaru.Tests.Devices.SCSI;
using System;
using Aaru.Console;
using Aaru.Decoders.SCSI;
using Aaru.Devices;
using Aaru.Helpers;
static class Plasmon
{
internal static void Menu(string devPath, Device dev)
{
while(true)
{
Console.Clear();
AaruConsole.WriteLine("Device: {0}", devPath);
AaruConsole.WriteLine("Send a Plasmon vendor command to the device:");
AaruConsole.WriteLine("1.- Send READ LONG command.");
AaruConsole.WriteLine("2.- Send READ SECTOR LOCATION command.");
AaruConsole.WriteLine("0.- Return to SCSI commands menu.");
AaruConsole.Write("Choose: ");
string strDev = Console.ReadLine();
if(!int.TryParse(strDev, out int item))
{
AaruConsole.WriteLine("Not a number. Press any key to continue...");
Console.ReadKey();
continue;
}
switch(item)
{
case 0:
AaruConsole.WriteLine("Returning to SCSI commands menu...");
return;
case 1:
ReadLong(devPath, dev);
continue;
case 2:
ReadSectorLocation(devPath, dev);
continue;
default:
AaruConsole.WriteLine("Incorrect option. Press any key to continue...");
Console.ReadKey();
continue;
}
}
}
static void ReadLong(string devPath, Device dev)
{
var relative = false;
uint address = 0;
ushort length = 1;
ushort bps = 512;
var physical = false;
var sectorCount = true;
string strDev;
int item;
parameters:
while(true)
{
Console.Clear();
AaruConsole.WriteLine("Device: {0}", devPath);
AaruConsole.WriteLine("Parameters for READ LONG command:");
AaruConsole.WriteLine("{0} Block Address: {1}", physical ? "Physical" : "Logical", address);
AaruConsole.WriteLine("Relative?: {0}", relative);
AaruConsole.WriteLine("Will transfer {0} {1}", length, sectorCount ? "sectors" : "bytes");
if(sectorCount)
AaruConsole.WriteLine("Expected sector size: {0} bytes", bps);
AaruConsole.WriteLine();
AaruConsole.WriteLine("Choose what to do:");
AaruConsole.WriteLine("1.- Change parameters.");
AaruConsole.WriteLine("2.- Send command with these parameters.");
AaruConsole.WriteLine("0.- Return to Plasmon vendor commands menu.");
strDev = Console.ReadLine();
if(!int.TryParse(strDev, out item))
{
AaruConsole.WriteLine("Not a number. Press any key to continue...");
Console.ReadKey();
continue;
}
switch(item)
{
case 0:
AaruConsole.WriteLine("Returning to Plasmon vendor commands menu...");
return;
case 1:
AaruConsole.Write("Physical address?: ");
strDev = Console.ReadLine();
if(!bool.TryParse(strDev, out physical))
{
AaruConsole.WriteLine("Not a boolean. Press any key to continue...");
physical = false;
Console.ReadKey();
continue;
}
AaruConsole.Write("Relative address?: ");
strDev = Console.ReadLine();
if(!bool.TryParse(strDev, out relative))
{
AaruConsole.WriteLine("Not a boolean. Press any key to continue...");
relative = false;
Console.ReadKey();
continue;
}
AaruConsole.Write("{0} Block Address?: ", physical ? "Physical" : "Logical");
strDev = Console.ReadLine();
if(!uint.TryParse(strDev, out address))
{
AaruConsole.WriteLine("Not a number. Press any key to continue...");
address = 0;
Console.ReadKey();
continue;
}
AaruConsole.Write("Transfer sectors?: ");
strDev = Console.ReadLine();
if(!bool.TryParse(strDev, out sectorCount))
{
AaruConsole.WriteLine("Not a boolean. Press any key to continue...");
sectorCount = true;
Console.ReadKey();
continue;
}
AaruConsole.Write("How many {0} to transfer?: ", sectorCount ? "sectors" : "bytes");
strDev = Console.ReadLine();
if(!ushort.TryParse(strDev, out length))
{
AaruConsole.WriteLine("Not a number. Press any key to continue...");
length = (ushort)(sectorCount ? 1 : 512);
Console.ReadKey();
continue;
}
if(sectorCount)
{
AaruConsole.Write("How many bytes to expect per sector?");
strDev = Console.ReadLine();
if(!ushort.TryParse(strDev, out bps))
{
AaruConsole.WriteLine("Not a number. Press any key to continue...");
bps = 512;
Console.ReadKey();
}
}
break;
case 2: goto start;
}
}
start:
Console.Clear();
bool sense = dev.PlasmonReadLong(out byte[] buffer, out byte[] senseBuffer, relative, address, length, bps,
physical, sectorCount, dev.Timeout, out double duration);
menu:
AaruConsole.WriteLine("Device: {0}", devPath);
AaruConsole.WriteLine("Sending READ LONG to the device:");
AaruConsole.WriteLine("Command took {0} ms.", duration);
AaruConsole.WriteLine("Sense is {0}.", sense);
AaruConsole.WriteLine("Buffer is {0} bytes.", buffer?.Length.ToString() ?? "null");
AaruConsole.WriteLine("Buffer is null or empty? {0}", ArrayHelpers.ArrayIsNullOrEmpty(buffer));
AaruConsole.WriteLine("Sense buffer is {0} bytes.", senseBuffer?.Length.ToString() ?? "null");
AaruConsole.WriteLine("Sense buffer is null or empty? {0}", ArrayHelpers.ArrayIsNullOrEmpty(senseBuffer));
AaruConsole.WriteLine();
AaruConsole.WriteLine("Choose what to do:");
AaruConsole.WriteLine("1.- Print buffer.");
AaruConsole.WriteLine("2.- Print sense buffer.");
AaruConsole.WriteLine("3.- Decode sense buffer.");
AaruConsole.WriteLine("4.- Send command again.");
AaruConsole.WriteLine("5.- Change parameters.");
AaruConsole.WriteLine("0.- Return to Plasmon vendor commands menu.");
AaruConsole.Write("Choose: ");
strDev = Console.ReadLine();
if(!int.TryParse(strDev, out item))
{
AaruConsole.WriteLine("Not a number. Press any key to continue...");
Console.ReadKey();
Console.Clear();
goto menu;
}
switch(item)
{
case 0:
AaruConsole.WriteLine("Returning to Plasmon vendor commands menu...");
return;
case 1:
Console.Clear();
AaruConsole.WriteLine("Device: {0}", devPath);
AaruConsole.WriteLine("READ LONG response:");
if(buffer != null)
PrintHex.PrintHexArray(buffer, 64);
AaruConsole.WriteLine("Press any key to continue...");
Console.ReadKey();
Console.Clear();
AaruConsole.WriteLine("Device: {0}", devPath);
goto menu;
case 2:
Console.Clear();
AaruConsole.WriteLine("Device: {0}", devPath);
AaruConsole.WriteLine("READ LONG sense:");
if(senseBuffer != null)
PrintHex.PrintHexArray(senseBuffer, 64);
AaruConsole.WriteLine("Press any key to continue...");
Console.ReadKey();
Console.Clear();
AaruConsole.WriteLine("Device: {0}", devPath);
goto menu;
case 3:
Console.Clear();
AaruConsole.WriteLine("Device: {0}", devPath);
AaruConsole.WriteLine("READ LONG decoded sense:");
AaruConsole.Write("{0}", Sense.PrettifySense(senseBuffer));
AaruConsole.WriteLine("Press any key to continue...");
Console.ReadKey();
Console.Clear();
AaruConsole.WriteLine("Device: {0}", devPath);
goto menu;
case 4: goto start;
case 5: goto parameters;
default:
AaruConsole.WriteLine("Incorrect option. Press any key to continue...");
Console.ReadKey();
Console.Clear();
goto menu;
}
}
static void ReadSectorLocation(string devPath, Device dev)
{
uint address = 0;
var physical = false;
string strDev;
int item;
parameters:
while(true)
{
Console.Clear();
AaruConsole.WriteLine("Device: {0}", devPath);
AaruConsole.WriteLine("Parameters for READ SECTOR LOCATION command:");
AaruConsole.WriteLine("{0} Block Address: {1}", physical ? "Physical" : "Logical", address);
AaruConsole.WriteLine();
AaruConsole.WriteLine("Choose what to do:");
AaruConsole.WriteLine("1.- Change parameters.");
AaruConsole.WriteLine("2.- Send command with these parameters.");
AaruConsole.WriteLine("0.- Return to Plasmon vendor commands menu.");
strDev = Console.ReadLine();
if(!int.TryParse(strDev, out item))
{
AaruConsole.WriteLine("Not a number. Press any key to continue...");
Console.ReadKey();
continue;
}
switch(item)
{
case 0:
AaruConsole.WriteLine("Returning to Plasmon vendor commands menu...");
return;
case 1:
AaruConsole.Write("Physical address?: ");
strDev = Console.ReadLine();
if(!bool.TryParse(strDev, out physical))
{
AaruConsole.WriteLine("Not a boolean. Press any key to continue...");
physical = false;
Console.ReadKey();
continue;
}
AaruConsole.Write("{0} Block Address?: ", physical ? "Physical" : "Logical");
strDev = Console.ReadLine();
if(!uint.TryParse(strDev, out address))
{
AaruConsole.WriteLine("Not a number. Press any key to continue...");
address = 0;
Console.ReadKey();
}
break;
case 2: goto start;
}
}
start:
Console.Clear();
bool sense = dev.PlasmonReadSectorLocation(out byte[] buffer, out byte[] senseBuffer, address, physical,
dev.Timeout, out double duration);
menu:
AaruConsole.WriteLine("Device: {0}", devPath);
AaruConsole.WriteLine("Sending READ SECTOR LOCATION to the device:");
AaruConsole.WriteLine("Command took {0} ms.", duration);
AaruConsole.WriteLine("Sense is {0}.", sense);
AaruConsole.WriteLine("Buffer is {0} bytes.", buffer?.Length.ToString() ?? "null");
AaruConsole.WriteLine("Buffer is null or empty? {0}", ArrayHelpers.ArrayIsNullOrEmpty(buffer));
AaruConsole.WriteLine("Sense buffer is {0} bytes.", senseBuffer?.Length.ToString() ?? "null");
AaruConsole.WriteLine("Sense buffer is null or empty? {0}", ArrayHelpers.ArrayIsNullOrEmpty(senseBuffer));
AaruConsole.WriteLine();
AaruConsole.WriteLine("Choose what to do:");
AaruConsole.WriteLine("1.- Print buffer.");
AaruConsole.WriteLine("2.- Print sense buffer.");
AaruConsole.WriteLine("3.- Decode sense buffer.");
AaruConsole.WriteLine("4.- Send command again.");
AaruConsole.WriteLine("5.- Change parameters.");
AaruConsole.WriteLine("0.- Return to Plasmon vendor commands menu.");
AaruConsole.Write("Choose: ");
strDev = Console.ReadLine();
if(!int.TryParse(strDev, out item))
{
AaruConsole.WriteLine("Not a number. Press any key to continue...");
Console.ReadKey();
Console.Clear();
goto menu;
}
switch(item)
{
case 0:
AaruConsole.WriteLine("Returning to Plasmon vendor commands menu...");
return;
case 1:
Console.Clear();
AaruConsole.WriteLine("Device: {0}", devPath);
AaruConsole.WriteLine("READ SECTOR LOCATION response:");
if(buffer != null)
PrintHex.PrintHexArray(buffer, 64);
AaruConsole.WriteLine("Press any key to continue...");
Console.ReadKey();
Console.Clear();
AaruConsole.WriteLine("Device: {0}", devPath);
goto menu;
case 2:
Console.Clear();
AaruConsole.WriteLine("Device: {0}", devPath);
AaruConsole.WriteLine("READ SECTOR LOCATION sense:");
if(senseBuffer != null)
PrintHex.PrintHexArray(senseBuffer, 64);
AaruConsole.WriteLine("Press any key to continue...");
Console.ReadKey();
Console.Clear();
AaruConsole.WriteLine("Device: {0}", devPath);
goto menu;
case 3:
Console.Clear();
AaruConsole.WriteLine("Device: {0}", devPath);
AaruConsole.WriteLine("READ SECTOR LOCATION decoded sense:");
AaruConsole.Write("{0}", Sense.PrettifySense(senseBuffer));
AaruConsole.WriteLine("Press any key to continue...");
Console.ReadKey();
Console.Clear();
AaruConsole.WriteLine("Device: {0}", devPath);
goto menu;
case 4: goto start;
case 5: goto parameters;
default:
AaruConsole.WriteLine("Incorrect option. Press any key to continue...");
Console.ReadKey();
Console.Clear();
goto menu;
}
}
}