Merge pull request #423 from gustavo-lara-molina/powerMonitor

Power monitor - adding missing events
This commit is contained in:
Gregor Biswanger
2020-06-02 22:04:03 +02:00
committed by GitHub
5 changed files with 223 additions and 1 deletions

View File

@@ -1,4 +1,5 @@
using System;
using System.Threading.Tasks;
namespace ElectronNET.API
{
@@ -64,6 +65,156 @@ namespace ElectronNET.API
}
private event Action _unlockScreen;
/// <summary>
/// Emitted when the system is suspending.
/// </summary>
public event Action OnSuspend
{
add
{
if (_suspend == null)
{
BridgeConnector.Socket.On("pm-suspend", () =>
{
_suspend();
});
BridgeConnector.Socket.Emit("register-pm-suspend");
}
_suspend += value;
}
remove
{
_suspend -= value;
if (_suspend == null)
BridgeConnector.Socket.Off("pm-suspend");
}
}
private event Action _suspend;
/// <summary>
/// Emitted when system is resuming.
/// </summary>
public event Action OnResume
{
add
{
if (_resume == null)
{
BridgeConnector.Socket.On("pm-resume", () =>
{
_resume();
});
BridgeConnector.Socket.Emit("register-pm-resume");
}
_resume += value;
}
remove
{
_resume -= value;
if (_resume == null)
BridgeConnector.Socket.Off("pm-resume");
}
}
private event Action _resume;
/// <summary>
/// Emitted when the system changes to AC power.
/// </summary>
public event Action OnAC
{
add
{
if (_onAC == null)
{
BridgeConnector.Socket.On("pm-on-ac", () =>
{
_onAC();
});
BridgeConnector.Socket.Emit("register-pm-on-ac");
}
_onAC += value;
}
remove
{
_onAC -= value;
if (_onAC == null)
BridgeConnector.Socket.Off("pm-on-ac");
}
}
private event Action _onAC;
/// <summary>
/// Emitted when system changes to battery power.
/// </summary>
public event Action OnBattery
{
add
{
if (_onBattery == null)
{
BridgeConnector.Socket.On("pm-on-battery", () =>
{
_onBattery();
});
BridgeConnector.Socket.Emit("register-pm-on-battery");
}
_onBattery += value;
}
remove
{
_onBattery -= value;
if (_onBattery == null)
BridgeConnector.Socket.Off("pm-on-battery");
}
}
private event Action _onBattery;
/// <summary>
/// Emitted when the system is about to reboot or shut down. If the event handler
/// invokes `e.preventDefault()`, Electron will attempt to delay system shutdown in
/// order for the app to exit cleanly.If `e.preventDefault()` is called, the app
/// should exit as soon as possible by calling something like `app.quit()`.
/// </summary>
public event Action OnShutdown
{
add
{
if (_shutdown == null)
{
BridgeConnector.Socket.On("pm-shutdown", () =>
{
_shutdown();
});
BridgeConnector.Socket.Emit("register-pm-shutdown");
}
_shutdown += value;
}
remove
{
_shutdown -= value;
if (_shutdown == null)
BridgeConnector.Socket.Off("pm-on-shutdown");
}
}
private event Action _shutdown;
private static PowerMonitor _powerMonitor;
private static object _syncRoot = new object();