mirror of
https://github.com/genesi/linux-legacy.git
synced 2026-05-20 13:57:31 +00:00
[ALSA] Change an arugment of snd_mpu401_uart_new() to bit flags
Change the 5th argument of snd_mpu401_uart_new() to bit flags instead of a boolean. The argument takes bits that consist of MPU401_INFO_XXX flags. The callers that used the value 1 there are replaced with MPU401_INFO_INTEGRATED. Signed-off-by: Takashi Iwai <tiwai@suse.de>
This commit is contained in:
committed by
Jaroslav Kysela
parent
140432fd2f
commit
302e4c2f9e
@@ -4215,7 +4215,7 @@ struct _snd_pcm_runtime {
|
||||
<programlisting>
|
||||
<![CDATA[
|
||||
struct snd_rawmidi *rmidi;
|
||||
snd_mpu401_uart_new(card, 0, MPU401_HW_MPU401, port, integrated,
|
||||
snd_mpu401_uart_new(card, 0, MPU401_HW_MPU401, port, info_flags,
|
||||
irq, irq_flags, &rmidi);
|
||||
]]>
|
||||
</programlisting>
|
||||
@@ -4242,15 +4242,36 @@ struct _snd_pcm_runtime {
|
||||
</para>
|
||||
|
||||
<para>
|
||||
The 5th argument is bitflags for additional information.
|
||||
When the i/o port address above is a part of the PCI i/o
|
||||
region, the MPU401 i/o port might have been already allocated
|
||||
(reserved) by the driver itself. In such a case, pass non-zero
|
||||
to the 5th argument
|
||||
(<parameter>integrated</parameter>). Otherwise, pass 0 to it,
|
||||
(reserved) by the driver itself. In such a case, pass a bit flag
|
||||
<constant>MPU401_INFO_INTEGRATED</constant>,
|
||||
and
|
||||
the mpu401-uart layer will allocate the i/o ports by itself.
|
||||
</para>
|
||||
|
||||
<para>
|
||||
When the controller supports only the input or output MIDI stream,
|
||||
pass <constant>MPU401_INFO_INPUT</constant> or
|
||||
<constant>MPU401_INFO_OUTPUT</constant> bitflag, respectively.
|
||||
Then the rawmidi instance is created as a single stream.
|
||||
</para>
|
||||
|
||||
<para>
|
||||
<constant>MPU401_INFO_MMIO</constant> bitflag is used to change
|
||||
the access method to MMIO (via readb and writeb) instead of
|
||||
iob and outb. In this case, you have to pass the iomapped address
|
||||
to <function>snd_mpu401_uart_new()</function>.
|
||||
</para>
|
||||
|
||||
<para>
|
||||
When <constant>MPU401_INFO_TX_IRQ</constant> is set, the output
|
||||
stream isn't checked in the default interrupt handler. The driver
|
||||
needs to call <function>snd_mpu401_uart_interrupt_tx()</function>
|
||||
by itself to start processing the output stream in irq handler.
|
||||
</para>
|
||||
|
||||
<para>
|
||||
Usually, the port address corresponds to the command port and
|
||||
port + 1 corresponds to the data port. If not, you may change
|
||||
|
||||
Reference in New Issue