Manuele Conti a5efb88d85 hw/timer/stm32f2xx_timer: fix periodic mode and CEN handling
RM0090 timers count from 0 to ARR inclusive, with a period of ARR + 1,
including ARR == 0. Wrap CNT while running, arm an absolute expiry, and
delete the QEMU timer when CEN is cleared.

Freeze CNT in stopped_cnt while CEN is clear so TIM_CNT writes while
stopped are preserved and resume on enable. Return a stopped CNT verbatim
even when it is greater than ARR. Reset also deletes any pending event.

Migration compatibility is not required for these machine types, so use
version 2 as both the current and minimum VMState version and serialize
stopped_cnt directly.

Add qtests covering the timer period, prescaler, stopped CNT, ARR == 0,
update generation, and system reset.

Signed-off-by: Manuele Conti <manuele.conti@archimede-energia.com>
Reviewed-by: Peter Maydell <peter.maydell@linaro.org>
Signed-off-by: Peter Maydell <peter.maydell@linaro.org>
2026-10-15 17:38:38 +01:00
..